Server Restarts During Ceph Performance Test

Problem Description

Table 1 Basic information

Item

Information

Source of the Problem

Online maintenance

Product

Kunpeng BoostKit

Sub-item

SDS

Service Scenario

Performance tuning

Component

Other

Output Time

2019-10-28

Author

Chen Xiaobo 00416232

Team

Kunpeng BoostKit

Review Result

Review passed

Review Date

2019-11-05

Release Date

2020-03-20

Keywords

Server restarts

Symptom

When the TaiShan 200 server is configured with the onboard NIC and 1822 NIC, the server restarts during the Ceph performance test.

Key Process and Cause Analysis

This problem is caused by the NIC driver.

Conclusion and Solution

  1. Check the onboard NIC driver. It is found that a kernel parameter of the onboard NIC driver needs to be configured.
  2. Upgrade the onboard NIC driver and add the irqpoll parameter to the kernel boot option.