我要评分
获取效率
正确性
完整性
易理解

Enabling the RAID Controller Card Cache

Purpose

Use the Redundant Array of Wimpy Blocks with Correction Codes (RAWBC) / Rechargeable Wireless Batteryless Capacitive Sensor (RWBC) features of a RAID controller card to achieve better performance.

Use the storcli tool to modify the cache settings of the RAID array.

  • Set Read Policy to Read ahead to use the cache of the RAID controller card for prefetch.
  • Set Write Policy to Write back to use the cache of the RAID controller card for write back instead of write through.
  • Set IO policy to Cached IO to use the cache of the RAID controller card to cache I/Os.

Procedure

  1. Configure the RAID controller card cache.
    1
    2
    3
    ./storcli64 /c0/vx set rdcache=RA
    ./storcli64 /c0/vx set wrcache=WB/AWB
    ./storcli64 /c0/vx set iopolicy=Cached
    

    WB/AWB in the ./storcli64 /c0/vx set wrcache=WB/AWB command depends on whether the RAID controller card has a supercapacitor. If no supercapacitor is available, use AWB.

  2. Check whether the configuration has taken effect.
    If the detailed information about the controller and logical drive is displayed, the configuration has taken effect.
    1
    ./storcli64 /c0 show