Hardware Tuning

Configure advanced BIOS settings to improve server performance.

Table 1 shows the recommended BIOS configuration. For details about how to access the BIOS of Kunpeng servers, see "Accessing the BIOS" in TaiShan Server BIOS Parameter Reference (Kunpeng 920 Processor).

Table 1 Recommended BIOS configuration

BIOS Option

Description

Recommended Value

Navigation Path

Power Policy

Sets the energy efficiency mode.

  • Efficiency: indicates the energy-saving mode, which supports Collaborative Processor Performance Control (CPPC) dynamic frequency modulation.
  • Performance: indicates the performance mode. In this mode, no dynamic frequency modulation (FM) is available, and the operating frequency is fixed at the nominal frequency.

Performance

BIOS > Advanced > Performance Config > Power Policy

Custom Refresh Rate

Sets the custom memory refresh rate.

64 ms

BIOS > Advanced > Memory Config > Custom Refresh Rate

Support Smmu

Enables or disables the SMMU function.

Disabled

BIOS > Advanced > MISC Config > Support Smmu

CPU Prefetching Configuration

Enables or disables CPU prefetching.

Enabled

BIOS > Advanced > MISC Config > CPU Prefetching Configuration