Rate This Document
Findability
Accuracy
Completeness
Readability

Typical Configuration

Table 1 lists the configuration of each component in the OpenStack scenario.

Table 1 Typical configuration in the OpenStack scenario

Node Type

Typical Configuration

Quantity

Remarks

Management node

Kunpeng server

  • Huawei Kunpeng 920 5220 processors
  • 256 GB or larger memory
  • 2 x 480 GB SATA SSD
  • Avago 3508 RAID controller cards
  • 1 x 10GE SP680 SmartNIC (four network ports)
  • Independent power supply

Three or more

PM: physical machines

VM: virtual machines

PM ≤ 50 and VM ≤ 500: 3 servers

PM ≤ 100 and VM ≤ 1000: 4 servers

PM ≤ 200 and VM ≤ 2000: 7 servers

PM ≤ 500 and VM ≤ 5000: 10 servers

PM ≤ 1000 and VM ≤ 10,000: 12 servers

Network node

Kunpeng server

  • Huawei Kunpeng 920 5220 processors
  • 256 GB or larger memory
  • 2 x 1.2 TB SATA SSD
  • Avago 3508 RAID controller cards
  • 2 x 10GE SP680 SmartNIC (four network ports)
  • 2 x GE LOM
  • Independent power supply

Two or more

Used only in the software SDN scenario. PM ≥ 200: four or more (recommended)

2 x 10GE: network service

2 x GE: network management

Compute node

Kunpeng server

  • Huawei Kunpeng 920 7260 processors
  • 256 GB or larger memory
  • 2 x 480 GB SATA SSD
  • Avago 3508 RAID controller cards
  • 1 x 10GE SP680 SmartNIC (There are four network ports, and every two of them are bonded together to form a logical port.)
  • Independent power supply

Two or more

  • The cluster scale is calculated based on the VM scale.
  • 2 x 10GE: network service + management
  • 2 x 10GE: network storage

Distributed storage node (Ceph)

Hot data: Kunpeng server

  • Huawei Kunpeng 920 5220 processors
  • 128 GB or larger memory
  • 2 x 480 GB SATA SSD
  • 12 x 3.2 TB NVMe SSD
  • 2 x 25GE NIC (LOM) (Every two network ports are bonded together to form a logical port and two logical ports are obtained. The two logical ports are connected to the public network and cluster network respectively.)
  • Independent power supply

Calculated based on the data volume

The calculation formula is as follows: Number of nodes = Planned data volume x 1.5 (Data expansion rate) x 1 (Data compression rate) x 3 (Three copies)/0.8 (Drive utilization)/0.9 (Drive number system conversion)/(12 (Number of drives) x 3.2 TB (Drive capacity))

Warm data: Kunpeng server

  • Huawei Kunpeng 920 5220 processors
  • 192 GB or larger memory
  • 2 x 480 GB SATA SSD
  • 2 x 3.2 TB NVMe SSD for acceleration
  • 12 x 8 TB HDD
  • 2 x 25GE/10GE NIC (LOM) (Every two network ports are bonded together to form a logical port and two logical ports are obtained. The two logical ports are connected to the public network and cluster network respectively.)
  • Independent power supply

Calculated based on the data volume

The calculation formula is as follows: Number of nodes = Planned data volume x 1.5 (Data expansion rate) x 1 (Data compression rate) x 3 (Three copies)/0.8 (Drive utilization)/0.9 (Drive number system conversion)/(12 (Number of drives) x 8 TB (Drive capacity))

Cold data: Kunpeng server

  • Huawei Kunpeng 920 5220 processors
  • 128 GB or larger memory
  • 2 x 480 GB SATA SSD
  • 36 x 8 TB HDD
  • 2 x 25GE/10GE NIC (LOM) (Every two network ports are bonded together to form a logical port and two logical ports are obtained. The two logical ports are connected to the public network and cluster network respectively.)
  • Independent power supply

Calculated based on the data volume

The calculation formula is as follows: Number of nodes = Planned data volume x 1.5 (Data expansion rate) x 1 (Data compression rate) x 3 (Three copies)/0.8 (Drive utilization)/0.9 (Drive number system conversion)/(36 (Number of drives) x 8 TB (Drive capacity))