Configuring Alarm Thresholds for Historical Reports
The threshold for historical reports can be customized for the Affinity Analyzer. During system running, a large number of reports or files occupy certain drive space. Once a threshold is exceeded, the system displays a message or disables the corresponding function.
Prerequisites
You have installed the Kunpeng DevKit.
Only the administrator devadmin can configure thresholds.
Procedure
- Click
in the upper right corner of the page. Choose Tool Settings > Affinity Analyzer. - Click Threshold Settings and set Report Warning Threshold and Maximum Report Threshold. See Figure 1.
- The value of Report Warning Threshold ranges from 1 to 49, and the default value is 40. The value of Maximum Report Threshold ranges from 2 to 50, and the default value is 50. The value of Maximum Report Threshold must be greater than that of Report Warning Threshold.
- When the number of reports reaches the Report Warning Threshold, the system prompts a message indicating that the number of reports exceeds the limit and you need to delete some to release the storage space. In this case, the use of the tool is not affected.
- When the number of reports reaches the Maximum Report Threshold, new tasks cannot be added and the system displays a message indicating that the number of reports has reached the maximum. In this case, you need to delete unnecessary historical reports.
Parent topic: Common Operations