Rate This Document
Findability
Accuracy
Completeness
Readability

Viewing Memory Overwriting Diagnosis Results

Prerequisites

A memory overwriting diagnosis task has been created and the analysis is complete.

Procedure

  1. In the System Diagnosis area on the left, click the name of the target analysis task.

    The node list is displayed.

  2. Click the name of the target node to view the analysis results.
    The Memory Overwriting tab page is displayed by default, as shown in Figure 1.
    Figure 1 Memory overwriting diagnosis

    Click View More to view the details.

  3. Click to switch the view. See Figure 2.
    Figure 2 List view
    • In the source code box, the line that contains the code with memory overwriting is highlighted.
    • You can use to switch between the code lines that have memory overwriting issues.
  4. Click the Task Information tab to view the detailed configuration and sampling information about the task on the current node.

    If a task fails to be executed, the failure cause will be displayed on the Task Information tab page.

    If some data fails to be collected but the overall task execution is not affected, you can view the exception message in Exception Information.

    Collection End Cause displays the reason why the data collection of the current task ends, for example, "Task collection times up" or "File size reaches the collection limit."