Environment Requirements
Hardware Requirements
Table 1 lists the hardware requirements.
Server |
TaiShan 200 server (model 2280) |
|---|---|
Processor |
Kunpeng 920 processor |
Core |
2 x 32-core |
CPU Frequency |
2600 MHz |
Memory Capacity |
12 x 16 GB |
Memory Frequency |
2666 MHz |
NIC |
IN200 NIC (4 x 25GE) |
Drive |
System drives: RAID 1 (2 x 960 GB SATA SSDs) Data drives: JBOD enabled in RAID mode (12 x 4 TB SATA HDDs) |
RAID Controller Card |
Avago SAS 3508 |
Software Requirements
Table 2 lists the software requirements.
Physical Networking Before Capacity Expansion
Figure 1 shows the physical networking before capacity expansion.
Table 3 describes the cluster plan before capacity expansion.
Cluster Node |
Management IP Address |
Public Network |
Cluster Network |
|---|---|---|---|
ceph1 |
192.168.2.156 |
192.168.3.156 |
192.168.4.156 |
ceph2 |
192.168.2.157 |
192.168.3.157 |
192.168.4.157 |
ceph3 |
192.168.2.158 |
192.168.3.158 |
192.168.4.158 |
Table 4 describes the client plan before capacity expansion.
Client |
Management IP Address |
Service Port IP Address |
|---|---|---|
client1 |
192.168.2.192 |
192.168.3.192 |
- Management IP Address: specifies the IP address used for
BMC management (address of the out-of-band management network port). - Cluster Network: specifies the internal IP address (of a 25GE network port) used for data synchronization between clusters.
- Public Network: specifies the external IP address (of a 25GE network port) for compute nodes to access the storage node (block devices).
- The clients and the front-end network of the cluster must be in the same network segment. 25GE network ports are recommended.
- Before expansion, the Ceph cluster is deployed on x86 servers. This document uses Huawei FusionServer Pro 2288H V5 servers as an example.
Physical Networking After Capacity Expansion
Figure 2 shows the physical networking after expansion.
Table 5 describes the cluster plan after capacity expansion.
Cluster Node |
Management IP Address |
Public Network |
Cluster Network |
|---|---|---|---|
ceph1 |
192.168.2.156 |
192.168.3.156 |
192.168.4.156 |
ceph2 |
192.168.2.157 |
192.168.3.157 |
192.168.4.157 |
ceph3 |
192.168.2.158 |
192.168.3.158 |
192.168.4.158 |
ceph4 |
192.168.2.197 |
192.168.3.197 |
192.168.4.197 |
ceph5 |
192.168.2.198 |
192.168.3.198 |
192.168.4.198 |
Table 6 describes the client plan after capacity expansion.
Client |
Management IP Address |
Service Port IP Address |
|---|---|---|
client1 |
192.168.2.192 |
192.168.3.192 |
- Management IP Address: specifies the IP address used for BMC management (address of the out-of-band management network port).
- Cluster Network: specifies the internal IP address (of a 25GE network port) used for data synchronization between clusters.
- Public Network: specifies the external IP address (of a 25GE network port) for compute nodes to access the storage node (block devices).
- The clients and the front-end network of the cluster must be in the same network segment. 25GE network ports are recommended.
- Before expansion, the Ceph cluster is deployed on x86 servers. This document uses Huawei FusionServer Pro 2288H V5 servers as an example.
- The ceph4 and ceph5 nodes to be added are deployed on TaiShan 200 servers (model 2280).